Three Mac minis in 2U, with A/B power, per-bay capture, and DFU control.

Mac minis, run like servers. Three bays in 2U with A/B power feeds through an automatic transfer switch, per-bay fusing and current telemetry, and the same capture pods as the WK chassis watching every screen. Mac minis are not included. Part of the rack line, listed on the enterprise store.

WM-2U03 Mac mini tray shown in three orthographic views

Documentation coming soon

Setup guides, wiring diagrams, and troubleshooting for the Mac mini tray are being written and will land here before it ships. The specifications below are current. If you need something specific in the meantime, get in touch.

What it does

  • Power like a datacenter. Two C14 feeds through an automatic transfer switch, with a relay, fusing, and current telemetry per bay.
  • The power button, solved. A servo-driven actuator works the physical button with timed tap, force-off, and DFU hold sequences, with a spring-return failsafe.
  • DFU without hands. A per-bay USB-PD controller on the DFU port adds programmatic reboot, DFU entry, and a serial console. Preliminary.
  • Watched like the racks. HDMI and USB capture per bay, using the same pods as the WK chassis ports.
  • Customer traffic stays passive. Three passive Ethernet passthroughs; tenant traffic never touches the tray's electronics.
  • Grows in the field. Start with the bare enclosure and add the managed electronics later; the upgrade kit is field-installable.

Front and rear

WM-2U03 Mac mini tray, front panel with three bays
WM-2U03 Mac mini tray, rear panel

Specifications

Configurations

SKUDescriptionPrice
WM-2U00EEnclosure only: no electronics, front USB passthrough and power buttons$349
WM-2U03Fully managed: built-in per-bay KVM capture and control$2,795
WM-2U03-UKUpgrade kit, enclosure to fully managed, field-installable$2,500

Pricing preliminary until release.

Power

ItemDetail
Feeds2 × C14 (A / B), automatic transfer switch
Per bayRelay, fusing, current telemetry
Input100 to 240 VAC · ~30 W idle · 500 W max
CoolingFanless: bottom-intake plenum, rear exhaust

Per-bay control

ItemDetail
DFU controlUSB-PD controller: reboot, DFU entry, serial console
Power buttonServo actuator: tap / force-off / DFU holds, spring-return failsafe
CaptureHDMI + USB, same pods as WK ports
Front panelPower button, RGB LED, label window

Chassis

ItemDetail
Customer traffic3 × passive Ethernet passthroughs
ServiceFront SVC USB-C to any bay's DFU path
IndicatorsFeed A / B, ID / STAT, recessed reset
Restore hostAutomated restore on the roadmap: design-partner program

Connectivity

ItemDetail
EthernetRedundant Ethernet inputs
ManagementSerial and USB management ports

† Preliminary. Subject to change before release.